Wall & Partition System Testing
We provide accredited independent wall and partition testing services to ensure compliance with the highest standards required.

Wall & Partition Fire Testing
UKTC provide UKAS accredited fire resistance testing of load bearing and non-load-bearing walls and partition systems to both British (BS) & European (EN) standards.
​
Products can be tested in a 3 metre wide furnace and up to 5m high at United Kingdom Testing & Certification, allowing manufacturers to prove performance beyond the standard 3x3m furnace tests available elsewhere in the UK.
​
We are accredited to test to the following standards at our UK based fire resistance laboratory:
​
-
BS EN 1364-1:2015
-
BS EN 1365-1:2012
-
BS 476-21:1987 § 8
-
BS 476-22:1987 § 5​

Loadbearing v Non-Loadbearing Wall Tests
Loadbearing Wall Fire Testing
To help against collapse or failure of a building, there is a requirement for load bearing systems to have a minimum standard of fire resistance. Such wall or partition wall must maintain the fire integrity and independent structural stability of buildings. The fire resistance of load bearing systems can be demonstrated through destructive fire test evidence.
The measurement for this is called Load-bearing Capacity (R). The walls ability to maintain a load. This is determined by measuring the vertical deflection of the wall.
Non-Loadbearing Wall Fire Testing
The spread of fire within a building can be restricted by using fire resisting walls and partition walls to separate the building into compartments and allow means of escape. The fire resistance of non-load bearing systems can be demonstrated through destructive fire test evidence.
Why manufacturers trust United Kingdom Testing & Certification
United Kingdom Testing and Certification is one of the UK's leading providers of wall system testing. We understand the need that you must develop new products and the importance of getting these products to market at just the right time.
​​
At UKTC, we understand that your time is valuable, which is why we provide fast turnaround times, with draft reports issued within 10 working days, without compromising on the rigour or accuracy of our testing processes.
Our Fire Resistance Testing Laboratory

-
8 fire resistance furnace frames.
-
Test specimens up to 5m tall.
-
Smoke leakage testing on the same site.