Acoustic Testing
The acoustic test suite is designed to measure airborne sound insulation performance of doorsets, walls, glazing, partitions and other building elements. All tests are performed under the BS EN ISO 10140 series and rated to BS EN ISO 717-1.
How laboratory acoustic testing works
Laboratory acoustic testing measures how much sound passes through a building element. The specimen sits between a source and receiver room where sound levels are measured across a range of frequencies. The result gives manufacturers, specifiers and technical teams the evidence they need to position products in the market for key projects.
The test specimen is installed between two adjoining test rooms, with sound generated in the source room and measured in the receiving room. This allows us to assess sound passing horizontally through vertical building elements such as walls and doorsets.
During testing, a controlled sound field is generated across a range of frequencies. Sound levels are measured on both sides of the specimen and the acoustic characteristics of the receiving room are taken into account. From this, the sound reduction performance of the complete construction can be determined across the frequency range.
The BS EN ISO 10140 Series
Testing is undertaken in accordance with the BS EN ISO 10140 series, with airborne sound insulation performance rated in accordance with BS EN ISO 717-1.
For manufacturers, this testing can help to:
demonstrate the acoustic performance of a wall or complete doorset;
compare different product constructions or configurations;
identify areas where further product development may be beneficial; and
generate performance data to support technical literature, specification and product development.