top of page
​UKTC's smoke leakage chamber enables comprehensive and UKAS accredited smoke leakage testing performed to either BS EN 1634-3:2004 or BS 476-31.1:1983.​​
TESTING /

Smoke Leakage Testing

​UKTC's smoke leakage chamber enables comprehensive and UKAS accredited smoke leakage testing performed to either BS EN 1634-3:2004 or BS 476-31.1:1983.​​

GET A QUOTE

Smoke Leakage Testing

The smoke leakage test is an important safety measure that determines how well your fire doors and shutters will keep you safe in case of emergencies. This examination looks at the possibility for hot or cold air flow through them when they're activated during fires.



Why do I require smoke leakage testing?


As an essential part of all building safety, doors require to perform various functions and achieve the correct the satisfactory level of performance as part of of the overall building outcome. Smoke Leakage testing is a critical process of your fire safety testing process. A fire door that is correctly halts and reduces the spread of flame, but allows a passageway for smoke is insufficient for the protection of life in the event of a fire incident.



What to expect from a smoke leakage test?


To evaluate smoke leakage at ambient temperatures, the test is conducted using a specially designed smoke leakage chamber that houses a partition to install the sample. The chamber uses fans to control the pressure exerted and includes a pressure transducer, a flow meter and digital displays to record pressure and leakage rates throughout the test. Leakage over the perimeter length of the opening element is used to determine the results.


It is possible to evaluate both positive and negative pressures at ambient temperature. This can be done by simply reversing the chamber control fan's polarity to demonstrate leakage rates at ambient temperatures from both directions; leakage readings are taken at 10 pascals (Pa), 25 Pa and 50 Pa.


​

Test Standards


BS 8214:2026 Guidance on Smoke Leakage Testing

The 2026 update to BS 8214 tightened the rules and expectations on smoke leakage measurements for fire and smoke control doors. The most significant change is that smoke leakage must be measured across the whole specimen including the threshold and not simply just the head and jambs as per the previous guidance. Learn more here.



How much does smoke leakage testing cost?


UKAS accredited smoke leakage tests cost approximately £2500 (ex-VAT) including the associated supporting construction. Prices can vary on unique test programmes for manufacturers whereas savings can be made when testing the same specimen for both smoke and fire.


UKTC's fire resistance laboratory is fully equipped with a smoke leakage chamber and 3x3m furnace to allow specimens to be subjected to both smoke and fire testing with minimal downtime, saving the manufacturer time and money.


For a quote tailored to your test requirements, contact a member of our team by clicking here.


We provide accredited independent fire door testing services and fire resistance testing for door hardware and ironmongery.

Doorsets and Hardware Testing

Start Now
We provide accredited independent wall and partition testing services to ensure compliance with the highest standards required.

Wall & Partition System Testing

Start Now
We provide accredited independent glazing systems testing services to ensure compliance with the highest standards required.

Glazing Systems Testing

Start Now
The purpose of fire resistance testing is to confirm compliance with building codes and standards, ensuring the seals maintain their protective properties during a fire.

Penetration Seals Testing

Start Now
The purpose of fire resistance tests on linear joint seals is to assess the effect of a linear joint seal on the integrity and insulation of the construction.

Linear Joint Seals Testing

Start Now
Horizontal floor & ceiling fire testing services from a UK-based laboratory.

Floors and Ceilings Testing

Start Now
Coming Soon to UKTC's laboratory and test facility, a purpose-built acoustic test suite in accordance with BS EN ISO 10140-5:2021.

Acoustic Testing

Start Now
This procedure specifies a method of test for determining the rection to fire performance of construction products when exposed to thermal attack by a single burning item (SBI).

Single Burning Item (SBI) Test

Start Now
This test identifies products that will not, or not significantly, contribute to fire, regardless of their end use.

Non-combustibility Test

Start Now
This method specifies a test for determining the ignitability of products by direct small-flame impingement under zero impressed irradiance using vertically oriented test specimens.

Flame Source Test

Start Now
This test determines the potential maximum total heat release of a product when completely burned, regardless of its end use.

Gross Heat of Combustion Test

Start Now

other tests we provide

Trusted to ensure

Underline_2.png

Our team consists of the brightest scientists, engineers, researchers and technicians from the built environment industry. We share a common goal - to enable greater protection of lives and assets - and are ready to help you.

SPEAK TO US

FREQUENTLY ASKED QUESTIONS

bottom of page